Contact AndersAckredited productions test for third party quality assurance of CIPP-liner projects.
The tests usually performed is measurement of wall thickness, ring stiffness or bending stiffness and residual styrene according to standardized methods in EN ISO 11296-4:2018.
The final quality of a CIPP-liner is very much dependent on the competence and experience of the entrepreneur. Swedish Water does therefore recommend that sampling of test pieces should be performed. A spot-check of the tested parameters is valuable for the client, so that the characteristics are fulfilling the requirements set in the procurement process.
The tests are performed according to the test standards described in EN ISO 11296-4:2018 and the order by the client:
Wall thickness: EN ISO 3126
Ring stiffness: ISO 7685
Bending stiffness: EN ISO 11296-4:2018, Annex B
Residual styrene: ISO 4901
The results are presesendet in a ackredited technical report, together with comparison to the requirements or the design values.