Contact person
Johan Post
TIC-ingenjör
Contact JohanEN 60332-3-24 is a fire test method whose test results form the basis for fire classification according to EN 45545-2 "Fire protection on railway vehicles – Part 2: Requirements for fire behaviour of materials and components".
Testing according to EN IEC 60332-3-24 examines the vertical flame spread when the cable is fire tested. Test results form a basis for fire classification according to EN 45545-2 "Railway vehicle fire safety - Requirements for fire safety of materials and components".
Series EN IEC 60332-3-21, EN IEC EN IEC 60332-3-21, EN IEC 60332-3-22, EN IEC 60332-3-23, EN IEC 60332-3-24 and EN IEC 60332-3-25 describe standardized test methods that previously formed basis for fire categories A / FR, A, B, C and D according to SS 424 14 75 "Cables - Testing of fire properties ".
SS 424 14 75 now refers to the European method for fire classification of cables, EN 13501-6.
The fire test lasts for 60 minutes. During the first 40/201) minutes, the cable is exposed to a burner of 20.5 kW. After the burner is extinguished, another 20/401) minutes may elapse before any remaining fire/glow is extinguished and the extent of fire-damaged length of the cable is measured. Before testing, the cable is mounted in 3.5-meter lengths on a test ladder. Depending on the cross-sectional area of the conductor, the cable lengths are mounted on the test ladder with or without spaces.
1) Exposure time 40 min refers to the methods EN IEC 60332-3-21, -22 and -23 while the exposure time 20 min refers to the methods EN IEC 60332-3-24 and -25.
The cable lengths are evenly distributed on the test ladder. During the fire test, the ladder with the cable lengthss are placed vertically against a wall in a combustion chamber. In front of the ladder the burner is placed at a distance of 7.5 cm from the cable lengths.
The fire test results are summarized in English in a test report delivered in digital format.
Video of the testing can also be obtained.
It is interesting and instructive to watch fire testing and therefore we welcome our clients to visit us at the test occasions.
Utrustningen för brandprovning av kablar beskrivs i EN IEC 60332-3-10. Den används för provning enligt EN 50399 och metodserien EN IEC 60332-3-21, -22, -23, -24 och -25.
Testresultat från brandprovning enligt EN 50399 och EN IEC 60332-3-serien är inte fullt jämförbara eftersom luftflöde och även uppbyggnad av provkroppar är olika, dessutom genererar EN 50399 analysdata från brandgaserna vilket EN IEC 60332-3-serien inte gör.
Serien EN IEC 60332-3-21, -22, -23, -24 och -25 beskriver olika varianter av brandprovning av kablar. Skillnad mellan metoderna är dels mängd icke-metallisk volym (l/m) som brandprovas, uppställning av provkroppar (hur kablarna najas på teststegen) samt duration av exponering för brännare.
Kablar med åtminstone en ledare med en tvärsnittsarea större än 35 mm2 brandprovas monterade med ett mellanrum mellan kabellängderna, kablar med ledarens tvärsnittsarea på 35 mm2 eller mindre, och optiska fiberkablar, monteras utan mellanrum mellan kabellängderna. För metoden -25 monteras dock kabellängderna alltid utan mellanrum.
Kablar som monteras utan mellanrum kan också monteras i flera lager på teststegen, beroende på hur många kabellängder som krävs för att uppnå stipulerad mängd icke-metalliskt material för brandprovningen.